Double Wall Black Stove Pipe Clearance

Subtract 3 4 for installed length.
Double wall black stove pipe clearance. Designed for installation with minimum clearance to combustibles 6 to walls 8 from top of horizontal run to ceiling. Dvl s double wall air insulated design reduces clearances to combustibles from 18 in. This double wall construction is cooler on the outside and thus lets you reduce combustible wall clearances to 6 and and combustible ceiling clearances down to 8. Double wall stove pipe features a limited lifetime warranty.
Most attractive double wall product on the market. Most of the double wall stove pipe allows for 6 clearance from wall combustibles and 8 from ceiling combustibles. When combining lengths remember to subtract 1 5 from each to account for overlap. No unsightly slots or vents the outer casing is constructed of satin coat steel.
This pipe has a clearance of only 6 to combustible materials and keeps flue gases warm for better draft. Clearance to non combustible materials is 0 but pipes should not actually touch cement bricks or other non combustibles. The dvl 6 x 48 double wall black pipe length is a component that is used in a typical venting installation. It is a 24 gauge black satin coat steel outer pipe with 430 stainless steel inner liner with a 016 thickness.
Constructed with a stainless steel inner wall. Available in 6 7 and 8 diameters. Using a heat shield on a single wall stovepipe allows you to reduce the clearances from 18 to 6 to the wall and 9 to the ceiling. Double wall stove pipe is used to make the connection from the chimney or chimney kit to the appliance in the final interior run.
Satin coat is attractive and durable when painted. Double wall stove pipe can reduce the clearance needed to combustibles in many situations and typically has a stainless steel inner wall that will provide a much loger time of service that a typical single wall setup. Double wall black stove pipes the clearance to combustible materials for double wall stove pipe such as standard drywall or wood is 6 to walls and 8 to ceilings. Dvl double wall stovepipe completes the venting system when used with one of duravent s chimney products such as duratech duraplus or duraplus htc.
Double wall pipe should not be cut. Single wall stove pipe requires an 18 clearance which typically means your wood stove sits further away from the wall and takes up valuable space within the room. Double walled or close clearance stove pipe is used to connect your stove to the chimney. The double wall construction keeps the outside cooler and thus reduces wall clearances to 6 inches and ceiling clearances to 8 inches.